E5MCPF8 Suspended beam and block floor – 150mm Insulation below screed

Build Up

External Masonry Cavity Wall

Masonry Outer Leaf (λ = 0.77)

Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK

Partial Fill Insulation

Beam and Block Floor

Lightweight Floor Block

150mm Insulation Below Screed (0.022W/mK)

 

This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:

England

  • Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
  • Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
  • Approved Document L2B (2010 edition incorporating amendments up to and including 2016)

NOTE: This LABC Registered Construction Detail should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.

Wales

  • Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)

NOTE: This LABC Registered Construction Detail should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.

 