Construction Details
P5PCFF2 Roof, Insulation At Rafter Level
Build Up
Party Masonry Cavity Wall
Separating Wall and Roof
2 x 100mm Aircrete Block (0.19W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK) density up to 40kg/m3
150mm insulation (λ = 0.044W/mK) between the rafters
50mm (λ =0.022W/mK) below the rafters
View DetailsP4PCFF2 Roof, Insulation At Ceiling Level
Build Up
Masonry Party Wall
Separating Wall and Roof
2 x 100mm Aircrete Block (0.19W/m²K) Party (Separating) Wall
Max. 100mm cavity fully filled with insulation (0.044W/mK) density up to 40kg/ m3
400mm Insulation (λ = 0.044W/mK) at Ceiling Level
View DetailsE18MCFF12 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
2 x 100mm Aircrete Block (0.19W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/Mk)
View DetailsE18MCFF9 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
View Details