Construction Details
E6MCFF1 Intermediate Floor Within a Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
View DetailsE7MCFF1 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Precast Concrete Floor Between Dwellings
View DetailsE18MCFF4 Masonry separating wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK Inner Leaf
Full Fill Insulation
2 x Dense Blockwork Leaves to Party (Separating) Wall
View DetailsE18MCFF1 Masonry separating wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK Inner Leaf
Full Fill Insulation
2 x Lightweight Blockwork Leaves to Party (Separating) Wall
View DetailsE17MCFF1 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Normal Corner
View DetailsE16MCFF1 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/Mk) between rafters
50mm insulation (0.022W/Mk) beneath rafters
View DetailsE13MCFF1 Pitched roof gable, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/Mk) between rafters
50mm insulation (0.022W/Mk) beneath rafters
View DetailsE12MCFF1 Pitched roof gable, insulation at ceiling level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Pitched Roof Gable
400mm insulation (0.044W/mK) at Ceiling Level
Ventilated Loft
View DetailsE11MCFF1 Pitched roof eaves, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Pitched Roof Eaves
150mm insulation (0.022W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
View DetailsE10MCFF1 Pitched roof eaves
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Pitched Roof Eaves
400mm insulation (0.044W/mK) at Ceiling Level
Ventilated Loft
View Details