P1PCFF2 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
Masonry Party Wall
2 x 100mm Aircrete Block (0.19W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
150mm Beam & Aircrete Block Infill
75mm Screed
Insulation Above Precast Beam and Block Floor
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
- Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
- Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
- Approved Document L2B (2010 edition incorporating amendments up to and including 2016)
NOTE: This LABC Registered Construction Detail should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.
Wales
- Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)
NOTE: This LABC Registered Construction Detail should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.
Architect downloads
p1pcff2_cad_file.dwg73.23 KB
Registered Detail certificates
p1pcff2_certificate.pdf712.85 KB
rcd_worksheet_157.pdf340.6 KB