E13SMEW3 Pitched Roof Gable Insulation at Rafter level
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ ≤ 0.15 W/mK)
Render & Insulation (λ = 0.022 W/mK)
Pitched Roof Gable
150mm insulation (0.044W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
View DetailsP5PCFF1 Roof, Insulation At Rafter Level
Build Up
Party Masonry Cavity Wall
Separating Wall and Roof
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK) density up to 40kg/m3
150mm insulation (λ = 0.044W/mK) between the rafters
50mm (λ =0.022W/mK) below the rafters
View DetailsP4PCFF1 Roof, Insulation At Ceiling Level
Build Up
Masonry Party Wall
Separating Wall and Roof
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
Max. 100mm cavity fully filled with insulation (0.044W/mK) density up to 40kg/ m3
400mm Insulation (λ = 0.044W/mK) at Ceiling Level
View DetailsP1PCFF5 In-Situ Concrete Ground Bearing Floor, Insulation Below Slab
Build Up
Masonry Party Wall
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
Ground Bearing Concrete Floor
Insulation Below Floor Slab
View DetailsP1PCFF3 Suspended Concrete Floor, Insulation Below Slab
Build Up
Masonry Party Wall
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
150mm Cast In-Situ Suspended Slab
Insulation Below Floor Slab
View DetailsP1PCFF1 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
Masonry Party Wall
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
150mm Beam & Aircrete Block Infill
75mm Screed
Insulation Above Precast Beam and Block Floor
View DetailsE18MCFF11 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
2 x 100mm Aircrete Block (0.19W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/Mk)
View DetailsE18MCFF8 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
View DetailsE17MCFF5 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Inverted Corner
View DetailsE16MCFF5 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Normal Corner
View Details