Construction Details
P5MCFF1 Separating wall and roof with insulation at rafter level
Build Up
Party Masonry Cavity Wall
Separating Wall and Roof
2 x Leaves Lightweight Blockwork Party (Separating) Wall
Cavity fully filled with insulation
150mm insulation (λ = 0.044W/mK) between the rafters
50mm (λ =0.022W/mK) below the rafters
View DetailsP4MCFF1 Separating wall and roof with insulation at ceiling level
Build Up
Masonry Party Wall
Separating Wall and Roof
2 x Leaves Lightweight Blockwork to Party (Separating) Wall
Cavity fully filled with insulation
400mm Insulation (λ = 0.044W/mK) at Ceiling Level
View DetailsE6MCPF2 Intermediate floor within a dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
View DetailsE6MCFF2 Intermediate Floor Within a Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
View DetailsE7MCPF2 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Precast Concrete Floor Between Dwellings
View DetailsE7MCFF2 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Precast Concrete Floor Between Dwellings
View DetailsE4MCPF2 Jamb
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Window Jamb
View DetailsE18MCPF5 Masonry separating wall – External wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Lightweight Concrete Block λ ≤ 0.60 W/mK Inner Leaf
Partial Fill Insulation
2 x Dense Blockwork Leaves to Party (Separating) Wall
View DetailsE18MCPF2 Masonry separating wall – External wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Lightweight Concrete Block λ ≤ 0.60 W/mK Inner Leaf
Partial Fill Insulation
2 x Lightweight Blockwork Leaves to Party (Separating) Wall
View DetailsE17MCPF2 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Inverted Corner
View Details