Construction Details
E20TFHY01 Exposed Floor
Psi Value = 0.015 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
...
View DetailsE20TFHY02 Exposed Floor
Psi Value = 0.012 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
Breather Membrane
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
...
E20TFHY03 Exposed Floor
Psi Value = 0.020 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/2K)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm...