Construction Details
E2TFHY01 Window Head
Psi Value = 0.053 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/m2K)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/m2K)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
View Details
E2TFHY02 Window Head
Psi Value = 0.046 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
Breather Membrane
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
20mm Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
20mm Low-e Air Cavity provided by 38mm Battens
Plasterboard
View Details
E2TFHY03 Window Head
Psi Value = 0.037 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
20mm Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
20mm Low-e Air Cavity provided by 38mm Battens
...
E3TFHY01 Window Sill
Psi Value = 0.075 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
E3TFHY02 Window Sill
Psi Value = 0.075 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
Breather Membrane
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
E3TFHY03 Window Sill
Psi Value = 0.068 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
View Details
E4TFHY01 Window Jamb
Psi Value = 0.047 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
E4TFHY02 Window Jamb
Psi Value = 0.047 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
Breather Membrane
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
E4TFHY03 Window Jamb
Psi Value = 0.040 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
View Details
E5TFHY01 Ground Floor
Psi Value = 0.029 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
...
View Details