The dos and don'ts of mains powered smoke alarms and battery alarms

News
Picture of smoke alarm fixed to the ceiling

Most properties in the UK have battery-operated smoke alarms, but mains powered smoke alarms interlinked between floors are the most reliable method of giving early warning in case of fire and must now be installed in all new homes.

Mains-wired smoke alarms are also required in certain types of alteration and extension work. Mount them in the circulation space at every floor level:

  • In loft conversions
  • When adding new habitable rooms (bedrooms, kitchens, living or dining rooms) above ground floor level
  • When adding a new habitable room at ground floor level that doesn’t have its own exit leading outdoors

Installing new interlinked smoke alarms can be disruptive, so think about the need for detection before you start work. Radio-linked alarms are acceptable; as long as the manufacturer can guarantee the battery back-up will last for 72 hours.

Smoke alarm DOs:

  • Ensure there's at least one alarm on every storey of the dwelling
  • Ensure there's an alarm within 7.5m of the door to every habitable room
  • Provide a heat detector to the kitchen if it's open plan to the escape route
  • Mount them 300mm away from walls and light fittings
  • Ensure the electrical installation of the units meets Part P requirements
  • Provide instructions to the end user

Smoke alarm DON'Ts:

  • Install them above staircases where testing and maintenance is dangerous
  • Site them in places where they can become very hot, cold, or subject to a lot of moisture or fumes (bathrooms, kitchens, garages - use a heat detector if need be)

Remember, there are additional requirements for large houses of two or more storeys where one of those storeys exceeds 200m2, so bear this in mind when working on footballers' mansions! If in any doubt, contact your local authority building control team to discuss.

Further information about fire safety

Also view: How to protect residents from carbon monoxide poisoning

 

Please Note: Every care was taken to ensure the information was correct at the time of publication. Any written guidance provided does not replace the user’s professional judgement. It is the responsibility of the dutyholder or person carrying out the work to ensure compliance with relevant building regulations or applicable technical standards.


This article was updated on 28 March 2022

Comments

Reply

Submitted 5 years 6 months ago

Hello - thanks for your comment.

Most smoke alarms manufacturers would suggest replacing the whole unit after 10 years or so. Gently cleaning the alarm with a vacuum cleaner every 6 months is usually adequate. When replacing, if there is a unit near the kitchen it would be better to replace it with a heat detector.

Regards,
John, LABC

The UNANSWERED Question above.

Submitted 1 year 8 months ago

I am suffering repleated bleeping,is it because the unit is life expired & time to BUY another one?

LABC Response

Submitted 1 year 7 months ago

Thank you for your enquiry.
“The repeated bleeping is indicative of a fault with the smoke alarm and should be investigated. It may require replacement.”

Kind Regards,
LABC Team

Smoke / Heat Alarm

Submitted 5 years 2 months ago

Hi, I live in a new 3 storey house. There is a wired smoke alarm in the hall and the 2 landings. My concern is, shouldn’t there be a heat Alarm in the open plan kitchen / Family Area / Dining Area?

Reply to: Smoke / Heat Alarm

Submitted 5 years 2 months ago

Hi Tim, thanks for your question.

The standard for smoke alarms BS 5839 part 6 has a minimum requirement for smoke alarms to be positioned in the circulation spaces at each floor level. In a three storey house there should be a protected stairway enclosure at each level. In addition to the minimum requirement, you can add a heat detector to the kitchen area to offer earlier detection. Hope that helps.

John, LABC

(No subject)

Submitted 5 years ago

Does a window in a ground floor habitable room count as an exit to outside?

Ground floor window

Submitted 5 years ago

Hi, thanks for your enquiry.

It's generally acceptable to escape from a ground floor window in a dwelling providing escape is available to a place free from the danger of fire. There is detailed guidance about the size of the window etc within Approved Documents volume 1 and 2.

If you would like guidance on a specific project, your local building control team will be pleased to provide free pre-application advice. You can find them by entering the postcode of your project in the 'find your council' bar at the top of our website.

Regards,

John, LABC

Still need Mains-wired?

Submitted 5 years ago

The LACORS guidance is now a decade old, yet some a Local Authorities still insist on sticking to the letter of its recommendations. At its time of writing there were no 10-year lithium battery sealed alarms available.
Now there are, so should an interlinked system of these with a rigorous testing schedule be sufficient for a shared house of 3-4 bedrooms on two storeys?

Reply to: Still need Mains-wired?

Submitted 5 years ago

Hi, thanks for the enquiry.

In relation to your suggestions about the smoke detectors, these should be directed to the MHCLG who are responsible for publishing the Building Regulations and the Approved Documents. There is a current review underway in relation to Approved Document B- Fire Safety. Most Local Authority Building Control departments would not generally use the LACORS guide in relation to compliance with the Building Regulations.

If you have a Building Regulation query about a particular project your local building control team will be pleased to offer pre-application advice. To obtain their contact details please enter your postcode in the 'find your council' bar at the top of our website.

Kind regards,
LABC

Smoke alarm location

Submitted 5 years ago

Hi! Is there an addition regulation to the 300mm when a smoke is situated near a AC unit or an MVHR outlet.
Thank you

Add new comment

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

Sign up to the building bulletin newsletter

Over 48,000 construction professionals have already signed up for the LABC Building Bulletin.

Join them and receive useful tips, practical technical information and industry news by email once every 6 weeks.

Subscribe to the Building Bulletin