Construction Details
E6MCPF3 Intermediate floor within a dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
View DetailsE7MCPF3 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Precast Concrete Floor Between Dwellings
View DetailsE4MCPF3 Jamb
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Window Jamb
View DetailsE18MCPF6 Masonry separating wall – External wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Dense Concrete Block λ ≤1.33 W/mK Inner Leaf
Partial Fill Insulation
2 x Dense Blockwork Leaves to Party (Separating) Wall
View DetailsE18MCPF3 Masonry separating wall – External wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Dense Concrete Block λ ≤1.33 W/mK Inner Leaf
Partial Fill Insulation
2 x Lightweight Blockwork Leaves to Party (Separating) Wall
View DetailsE17MCPF3 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Inverted Corner
View DetailsE16MCPF3 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Normal Corner
View DetailsE13MCPF3 Pitched roof gable, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
View DetailsE12MCPF3 Pitched Roof Gable, Insulation at Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Pitched Roof Gable
400mm insulation (0.044W/mK) at Ceiling Level
Ventilated Loft
View DetailsE11MCPF3 Pitched roof eaves, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Pitched Roof Eaves
150mm insulation (0.022W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
View Details