Construction Details
E5TFHY02 Ground Floor
Psi Value = 0.026 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented ...
E5TFHY03 Ground Floor
Psi Value = 0.026 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
...
E6TFHY01 Intermediate Floor
Psi Value = 0.063 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
E6TFHY02 Intermediate Floor
Psi Value = 0.056 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
Breather Membrane
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
E6TFHY03 Intermediate Floor
Psi Value = 0.054 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
View Details
E7TFHY01 Separating Floor
Psi Value = 0.079 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
E7TFHY02 Separating Floor
Psi Value = 0.092 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
Breather Membrane
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
E7TFHY03 Separating Floor
Psi Value = 0.072 W/mK
Build Up
Brick Outer Leaf (λ = 0.77W/m2K)
50mm Air Cavity, vented
BOOST’R HYBRID
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/m2K)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
Plasterboard
E10TFHY01 Cold Roof
Psi Value = 0.040 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
BOOST’R HYBRID (R = 1.35 m2K/W)
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
Vapour Control Layer
Service Void provided by Battens
Plasterboard
...
View DetailsE10TFHY02 Cold Roof
Psi Value = 0.021 W/mK
Build Up - External Timber Frame Wall
Brick Outer Leaf (λ = 0.77W/mK)
50mm Air Cavity, vented
Breather Membrane
OSB
HYBRIS between 140mm Studs (λ = 0.033 W/mK)
Low-e Air Cavity
HCONTROL HYBRID (R = 1.90 m2K/W)
Low-e Air Cavity provided by 38mm Battens
...