Construction Details
P5MCFF1 Separating wall and roof with insulation at rafter level
Build Up
Party Masonry Cavity Wall
Separating Wall and Roof
2 x Leaves Lightweight Blockwork Party (Separating) Wall
Cavity fully filled with insulation
150mm insulation (λ = 0.044W/mK) between the rafters
50mm (λ =0.022W/mK) below the rafters
View DetailsP4MCFF1 Separating wall and roof with insulation at ceiling level
Build Up
Masonry Party Wall
Separating Wall and Roof
2 x Leaves Lightweight Blockwork to Party (Separating) Wall
Cavity fully filled with insulation
400mm Insulation (λ = 0.044W/mK) at Ceiling Level
View DetailsE6MCFF2 Intermediate Floor Within a Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
View DetailsE7MCFF2 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Precast Concrete Floor Between Dwellings
View DetailsE18MCFF5 Masonry separating wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Lightweight Concrete Block λ ≤ 0.60 W/mK Inner Leaf
Full Fill Insulation
2 x Dense Blockwork Leaves to Party (Separating) Wall
View DetailsE18MCFF2 Masonry separating wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Lightweight Concrete Block λ ≤ 0.60 W/mK Inner Leaf
Full Fill Insulation
2 x Lightweight Blockwork Leaves to Party (Separating) Wall
View DetailsE17MCFF2 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Inverted Corner
View DetailsE16MCFF2 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Normal Corner
View DetailsE13MCFF2 Pitched roof gable, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/Mk) between rafters
50mm insulation (0.022W/Mk) beneath rafters
View DetailsE12MCFF2 Pitched roof gable, insulation at ceiling level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Pitched Roof Gable
400mm insulation (0.044W/mK) at Ceiling Level
Ventilated Loft
View Details