Construction Details
LABC Registered Construction Details are only valid for use with building work intended to follow the guidance in the following:
England
- Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
- Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
- Approved Document L2B (2010 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.
Wales
Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.
E3MCPF3 Sill
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Window Sill
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
...
View DetailsE2MCPF3 Independent Concrete Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Independent Concrete Lintel
Soffit Insulation
This LABC Registered Construction Detail is only valid for use with building work intended to follow the...
View DetailsE1MCPF3 Insulated Steel Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Partial Fill Insulation
Steel Lintel with Perforated Baseplate
(Insulated Soffit)
This LABC Registered Construction Detail is only valid for use with building work intended to follow the...
View DetailsE18MCFF6 Masonry separating wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Dense Concrete Block λ ≤1.33 W/mK Inner Leaf
Full Fill Insulation
2 x Dense Blockwork Leaves to Party (Separating) Wall
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE18MCFF3 Masonry separating wall
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Dense Concrete Block λ ≤1.33 W/mK Inner Leaf
Full Fill Insulation
2 x Lightweight Blockwork Leaves to Party (Separating) Wall
This LABC Registered Construction Detail is only valid for use with building work intended...
View DetailsE17MCFF3 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Inverted Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
Approved... View DetailsE16MCFF3 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Normal Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
Approved... View DetailsE13MCFF3 Pitched roof gable, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/Mk) between rafters
50mm insulation (0.022W/Mk) beneath rafters
This LABC Registered Construction Detail is only valid for...
View DetailsE12MCFF3 Pitched roof gable, insulation at ceiling level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Pitched Roof Gable
400mm insulation (0.044W/Mk) at Ceiling Level
Ventilated Loft
This LABC Registered Construction Detail is only valid for use with building work...
View DetailsE11MCFF3 Pitched roof eaves, between and under rafter insulation
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Pitched Roof Eaves
150mm insulation (0.022W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
This LABC Registered Construction Detail is only valid for...
View Details