E18MCPF8 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Partial Fill Insulation
Proprietary Insulated Firestop (λ = 0.044W/mK)
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0...
View DetailsE18MCPF7 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Partial Fill Insulation
Proprietary Insulated Firestop (λ = 0.044W/mK)
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0...
View Details